IMPORTANT INFORMATION CONCERNING THE INSTALLATION OF THE APPLIANCE
The hob can be installed by itself, in an isolated position or inserted between two kitchen units or between one kitchen unit
and a wall. Furthermore the back wall and surrounding surfaces must resist a temperature of 65 K.
To prevent the plastic layer which covers the kitchen unit from ungluing, the glue used to join the two surfaces together must
resist temperatures of up to 150 °C
The installation of the appliance must be carried out according to the norms in force of the country concerned and the
appliance must be installed in a well ventilated place.
This appliance is not equipped with devices to remove the products of combustion. The appliance must therefore be
connected following the norms for installation mentioned above. Special attention must be paid to the information below
regarding aeration and ventilation of the premises.
To guarantee that the appliance works correctly it is necessary that the place where the appliance is installed is continuously ventilated.
The volume of the premises must not be less than 25 m³ and the quantity of air needed must be based on the regular combustion of
gas and on the ventilation of the premises. The natural flow of air will take place through permanent openings made in the wall of the
premises to be ventilated: these openings will be connected to the outside and must have a minimum section of 100 cm² ( see Fig. 2 ).
These openings must be made in such a way that they cannot be obstructed.
The cooking appliances that use gas must always remove the products of combustion via a hood linked to chimneys, chimney flues or
via a direct connection to the outside ( see Fig. 3 ). If it is not possible to fit a hood it is possible to use a fan, fitted on the window or
facing directly outside, which operates when the appliance is in use. ( see Fig. 4 ). In this way the norms in force of the country
concerned regarding the ventilation of premises are strictly followed.
1)
Remove n°2 screws fixing worktop as shown in fig.5
2)
Place front part of the backguard and attach it from bottom side with the two removed screws (point 2) as shown in fig .6
3)
Fix the front part of the backguard with the screws supplied with the backguard kit (fig.7)
4)
Assemble back part with front part of the backguard and fix them with a screws supplied with the backguard kit (fig.8)
Before connecting the appliance to the gas supply you first need to remove the plastic protective plug for the gas supply which
is inserted under pressure in the gas inlet connection. To remove the plug simply unscrew it.
Then make sure that the details shown on the label on the lower part of the case are compatible with those of the gas supply.
A label on the last page of this manual and on the lower part of the case indicates the conditions for regulating the appliance:
type of gas and pressure used.
IMPORTANT: This appliance must be installed in accordance with the norms in force of the country concerned and it must only
be used in a well-ventilated place.
ATTENTION: Remember that the gas inlet connection for the appliance is threaded 1/2 gas cylindrical male in accordance with
the norms UNI-ISO 228-1. (Fig. 10)
Before carrying out any maintenance work, disconnect the appliance from the gas and electric supply.
- CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:
To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig. 9) using an adjustable spanner of 7 mm and change the nozzles with those designed
for the new gas supply according to the information given in TABLE N° 2 shown below.
ATTENTION: After carrying out the changes described above, the technician must put the label corresponding to the new gas
supply on the appliance to take the place of the old label. This label is found in the bag containing spare nozzles.
TABLE N°2: Adapting to different types of gas
Burner
Types of Gas
Natural G20
Auxiliary
Butane G30
Propane G31
Natural G20
Semi-Rapid Butane G30
Propane G31
Natural G20
Rapid
Butane G30
Propane G31
Dual
Natural G20
Inner
Butane G30
Propane G31
Dual
Natural G20
Outer
Butane G30
Propane G31
VENTILATION OF THE PREMISES
POSITION AND VENTILATION
BACKGUARD INSTALLATION INSTRUCTION
CONNECTING THE APPLIANCE TO THE GAS SUPPLY
ADAPTING TO DIFFERENT TYPES OF GAS
Pressure
Nozzle
Diameter
mbar
1/100 mm.
20
77
30
50
37
50
20
101
30
66
37
66
20
129
30
87
37
87
20
70
30
46
37
46
20
2x110
30
2x69
37
2x69
APPLIANCE CATEGORY: II2H3+
Rater Capacity
g/h
l/h
kw
-
95
1
73
-
1
71
-
1
-
167
1,75
127
-
1,75
125
-
1,75
-
286
3
218
-
3
214
-
3
-
76
0,8
58
-
0,8
57
-
0,8
-
419
4,4
298
-
4,1
293
-
4,1
8
Reduced
Capacity
kcal/h
kw
kcal/h
1/100 mm.
860
0,48
413
860
0,48
413
860
0,48
413
1505
0,6
516
1505
0,6
516
1505
0,6
516
2580
1,05
903
2580
1,05
903
2580
1,05
903
688
0,48
413
688
0,48
413
688
0,48
413
3784
1,8
1548
3526
1,8
1548
3526
1,8
1548
by-pass
Diameter
34 reg.
34
34
36 reg.
36
36
52 reg.
52
52
34 reg.
34
34
65 reg.
65
65