SELECT THE BEST LOCATION
2
  There should not be any heat source or steam near the unit.
  A place where air circulation in the room is good.
  A place where drainage can be easily done.
  A place where noice prevention is taken into consideration.
  Do not install the unit near the door way.
  Ensure the spaces indicated by arrows from the wall, ceiling,
fence or other obstacles.
  Recommended installation height for indoor unit shall be at least
800 mm.
  Must install on a vertical wall.
  When install electrical equipment at wooden building of metal
lath or wire lath, according to electrical facility technical standard,
no electrical contact between equipment and building is allowed.
Insulator must be installed in between.
  Do not install the unit at outdoor. This is designed for indoor
installation only.
Required space for installation
100 mm
or more
HOW TO FIX INSTALLATION
3
PLATE
The mounting wall is strong and solid enough to prevent it from
More than 375
Wall
5
≥1556 from
ground
70
The centre of installation plate should be at more than 375 mm at
right and left of the wall.
The distance from installation plate edge to ground should more
than 1556 mm.
Always mount the installation plate horizontally plate by aligning the
marking thread and using a level gauge.
Mount the installation plate on the wall with 6 sets of plug, bolt and
washer (all non-supply) with size M8.
4
100 mm
or more
100 mm
or more
vibration
(Unit in mm)
More than 375
Wall
5
Installation
plate 1
Indoor Unit
body
Bolt -
size M8
Installation
160
200
plate 4
TO DRILL A HOLE IN THE
4
WALL AND INSTALL A
SLEEVE OF PIPING
1. Insert the piping sleeve to the hole.
2. Fix the bushing to the sleeve.
3. Cut the sleeve until it extrudes about 15 mm from the wall.
When the wall is hollow, please be sure to use the sleeve
for tube assembly to prevent dangers caused by mice biting
the connection cable.
4. Finish by sealing the sleeve with putty or caulking compound at
the fi nal stage.
Wall
Indoor
Sleeve for tube
assembly
ø70 mm through hole
INDOOR UNIT INSTALLATION
5
Access to Internal Components
WARNING
This section is for authorized and licensed electrician/water
system installer only. Work behind the front plate secured by
screws must only be carried out under supervision of qualifi ed
contractor, installation engineer or service person.
Please follow the steps below for take out front plate. Before
removing the front plate of indoor unit, always switch off all power
supply (i.e. indoor unit power supply, heater power supply and Tank
Unit power supply).
1. Remove the 2 mounting screws which located at bottom of the
front plate.
2. Gently pull the lower section of the front plate towards you to
remove the front plate from left and right hooks.
3. Hold the left edge and right edge of front plate to lift up front
plate from hooks.
Screws
CAUTION
Outdoor
15 mm
Approx. 5 - 7 mm
Bushing for tube assembly
Putty or caulking compound
Hook
Lift up

Advertenties