z 6 V batteries
If a battery is measured in the voltage range 2.0–7.5 V, then you can
only select Program 1.
z 12 V batteries and revival
If a battery is identified as being in the critical voltage range from
7.5–10.5 V, then the device will check whether it is a fully-charged 6 V
battery or a discharged 12 V battery.
Press the program selector button
The device carries out a test measurement procedure with a pulsed
charging current. The display will continue to show:
If, once the test measurement procedure is complete the display doesn't
reach more than 10.5 V, then the 12 V battery is defective.
If more than 10.5 V is reached during the test measurement procedure,
then this is a 12 V battery. The charging process will then start with
revival, the device switches to further charging stages. The display will
show:
The revival procedure is identical for all 12 V charging programs.
z Selecting programs
Please note:
If a battery is identified in the voltage range of 2.0–7.5 V, then programs
2-3-4 cannot be selected. The charging process continues automatically.
Depending on the program selected, the charging characteristics for
voltage, time and temperature are monitored. With diagnosis program,
revival mode and trickle charging.
Program
1
2
3
4
16
GB/IE/NI
, to select a program.
11
max. (V)
7.3 V
14.4 V
14.4 V
14.7 V
max. (A)
0.8 A
0.8 A
5.0 A
5.0 A