THERMO TECHNICAL CHARACTERISTICS
Thermal power output
Thermal power transferred to the water
Yield / Effi ciency
Emissions CO 13% O
2
Fume temperature
Fuel consumption
Draught
Hopper capacity
Water content
Maximum operating pressure of the water
Maximum operating temperature of the water
Autonomy
Heatable volume *
Smoke outlet pipe diameter (male)
Air intake pipe diameter (male)
Weight including packaging
TECHNICAL DATA FOR SIZING THE FLUE which must, in any case, comply with the guidelines of
this sheet and the installation rules for each product
Thermal power output
Temperature of fumes on exit from the discharge
pipe
Minimum draught
Fume fl ow capacity
* The heatable room dimensions are calculated on the basis of home insulation in compliance with Italian law 10/91, and subse-
quent changes together with an expected heat output of 33 Kcal/m³ per hour.
ELECTRICAL CHARACTERISTICS
Power supply
On/off switch
Average power consumption
Power consumption during ignition
Protection on mains power supply* (see page 48)
Protection on electronic circuit board
N.B.
1) keep in mind that external devices can cause interference to the operation of the circuit board.
2) warning: activity on live components, maintenance and/or checks must be carried out by qualifi ed personnel.
(before carrying out any maintenance, disconnect the appliance from the mains electricity)
3) In case of problems with the electrical grid, consult an electrician to evaluate the installation of a sine-wave UPS of at
least 800 Va. Power variations greater than 10% can cause problems for the product.
The above data are indicative and are those resulting during certifi cation on the part of the notifi ed body.
EDILKAMIN s.p.a. reserves the right to change the products at its discretion without notice.
GENERAL INFORMATION
MAXIMA 14
Nominal power
15
14
90
0,017
92
3,3
12 - 5
30
MAXIMA 14
Nominal power
14
120
12
303-5
according to EN
Reduced power
Nominal power
4,6
4
92
90,8
0,063
0,021
47
1,0
5,7
100
70
1,5
90
97
365
100
40
475
Reduced power
Nominal power
4
60
0-5
8
230Vac +/- 10% 50 Hz
si
150 W
400 W
T2A, 250 Vac, 5x20 Fuse
T2A, 250 Vac, 5x20 Fuse
- 49
-
MAXIMA 24
Reduced power
26
7,7
24
7
91,8
0,086
96
54
1,7
12 - 5
100
70
1,5
90
17
57
625
100
40
475
MAXIMA 24
Reduced power
24
7
120
70
0-5
10
7,3
kW
kW
%
%
°C
kg/h
Pa
kg
Litres
bar
°C
hours
3
m
mm
mm
kg
kW
°C
Pa
g/s