Pump installation and connection of the hoses (B, D)
Install the pump (4) as horizontally as possible. Raised installation can prevent the intake of dirt particles from the
bottom of the basin.
− Slightly loosen the union nut (14) at the Y distributor (15).
− Screw the reduction piece (16) on the pump (4) and insert the O-ring (17).
− Tighten the union nut (14) at the Y distributor (15).
− Screw the hose connection (19) on the Water Jet Lightning (1).
− Slide a hose clip (10) over the hose (6).
− Slide the hose (6) on the hose adapter (19) and secure with a hose clip (10).
− Connect the other end of the hose to the Y distributor (15) and secure with a hose clip (10).
Pos: 90 /Lampen/Wasserspieltechnik/Water Jet Lightning/Aufstellen Trafo und Steuerungsbox Water-Jet-Lightning @ 8\mod_1220884513083_121.doc @ 52067 @
Installing the 12 V control box
Variant 1 (F)
− Push the full length of the ground stake (8) into the ground at the desired position.
− Slide the 12 V control box (2) on the ground stake (8).
Variant 2 (G)
− Screw the 12 V control box (2) to the housing of the 12 V control box (2) on the base using 4 screws (21) (not
contained in the scope of delivery) through the screw gaps (22).
Setting up the transformer (H):
Place the transformer (5) close to the 12 V control box (2).
Note: Ensure that the cables are routed pull-relieved!
Pos: 91 /Alle Produkte/Dummy_module/Abstand 6 pt @ 7\mod_1196627997106_0.doc @ 41651 @
Pos: 92 /Alle Produkte/Überschriften/H1 Elektrische Installation @ 8\mod_1219935543509_121.doc @ 51295 @
Electrical installation
Pos: 93 /Lampen/Wasserspieltechnik/Water Jet Lightning/INS_Water-Jet-Lightning @ 8\mod_1221039895037_121.doc @ 52213 @
Connect the Water Jet Lightning with the 12 V control box and the transformer (H, I)
− Insert the pump plug (23) from the plug and the plugs (24) of the two Water Jet Lightning units into the respective
sockets for the pump (25) and the Water Jet Lightning (26) at the 12 V control box (2).
− Screw-connect the plug (27) of the transformer connection cable on the secondary side to the socket (28) at the rear
of the 12 V control box (2) and screw tighten with the union nut (29).
− Place the protection hood (3) over the 12 V control box (2).
Note: If you only want to operate one of the two Water Jet Lightning systems, plug the jumper plug (49) into the second
free socket (26).
n
Pos: 94 /Alle Produkte/Dummy_module/Abstand 6 pt @ 7\mod_1196627997106_0.doc @ 41651 @
Pos: 95 /Alle Produkte/Überschriften/H1 Inbetriebnahme @ 7\mod_1196625111244_121.doc @ 41417 @
Start-up
Pos: 96 /Lampen/Wasserspieltechnik/Water Jet Lightning/INB_Water-Jet-Lightning @ 8\mod_1221039989365_121.doc @ 52239 @
Caution! Do not damage the unit.
Protective measures: Never run the pump without water. Otherwise the pump will be destroyed.
Switching on the unit (J): Plug the power plug (30) of the transformer into the socket.
− The unit will start with program 1 (see chapter 'Control/Operation').
Switching off the unit (J): Pull the power plug (30) of the transformer.
Pos: 97 /Lampen/Wasserspieltechnik/Water Jet Lightning/Ausrichten Water-Jet-Lightning @ 8\mod_1221040206242_121.doc @ 52317 @
Alignment of the Water Jet Lightning and setting the intensity of the water jet (L, M)
Prior to starting work, disconnect the power plugs of all units in the water (J)!
Adjusting the angle of inclination (L)
The diagram shows the shapes of the water jet at various angles of inclination of the Water Jet Lightning.
− Undo the fastening screw (34) at the unit foot (33).
− Swing the Water Jet Lightning to the desired angle of inclination.
− Tighten the fastening screw (34) at the unit foot (33).
Setting the water jet (M)
For the Water Jet Lightning, the intensity of the water jet can be set at the valves of the Y distributor (9).
− Turn the respective valve clockwise: to reduce the water flow.
− Turn the respective valve counter-clockwise: to increase the water flow.
Pos: 98 /Alle Produkte/Dummy_module/Abstand 6 pt @ 7\mod_1196627997106_0.doc @ 41651 @
Pos: 99 /Alle Produkte/Überschriften/H1 Bedienung @ 7\mod_1196625148604_121.doc @ 41443 @
14