The battery does not charge up or its
autonomy has been reduced.
The motor is running but it does
not spray
The motor works but the spray does
not reach the pressure or spraying
is irregular.
The motor does not stop when the
handle is released.
The handle does not close
The motor runs intermittently when
spraying.
WARRANTY
8
Our goods have warranty, from the date of purchase by the user, against any manufacturing or material defect. The warranty is
strictly limited to free replacement of parts that our services consider defective. The warranty shall not apply in case of improper
use of our materials, disassembly and/or alterations performed to our devices, and to those parts of normal wear and tear that
require maintenance The warranty shall not apply in case of negligence, imprudence and irrational use of the material. Dispatch
and transportation costs of parts under warranty as well as workmanship that were not performed in our factory shall be borne
by the user. To invoke this warranty, send us the part subject matter of the claim, carriage free, together with the receipt or the
purchasing invoice.
9
EC AND UKCA DECLARATION OF CONFORMITY
We,
Goizper Group - C/Antigua 4 – E-20577 Antzuola - Spain
declare under our sole liability that this product complies with Machinery Directive 2006/42/EC and 2009/127/EC,
Electromagnetic Compatibility Directive 2014/30/EU and RoHS Directive 2011/65/EU, in compliance with the harmonized EN
ISO 19932-1:2014; EN ISO 19932-2:2014 and EN ISO 14982:2009.
Antzuola, October 2023.
Aitziber Uriarte, Technical Director
The charger is the original charger and works correctly. Check the
battery charge section.
The battery is old. Its service life is nearing its end (battery life
<65% of nominal)
The battery is new
Clean the hydraulic circuit
The amount of fluid in the sprayer
The recommended working positions for each nozzle
Cleaning the suction filter of the tank (Ref. 1397)
Hydraulic connections and leakages
Air in the hydraulic circuit
The condition of the nozzle
Check if the pump or the electronics are damaged
The amount of fluid in the sprayer
Cleaning the suction filter of the tank (Ref. 1397)
Air in the hydraulic circuit
Hydraulic connections and leakages
Check if the pump is damaged
The condition of the joints
The selected nozzle has a nominal flow rate less than that
recommended in the nozzle table.
Cleaning the nozzle, its filter and handle filter. [3.6]
Replace the charger if it fails to work
Replace the battery
Contact the distributor
Raise the appliance to table height and place the handle in a
lower height, with the appliance switched on and the handle
activated. Hold this position for a few seconds
Fill the sprayer with the product to be sprayed
Use the nozzles and work positions recommended in the
nozzle selection tables T.1 and T.2.
Clean the filter if necessary
Tighten any joint if necessary
Stop the motor and restart the equipment to spray a few
seconds with the lance pointing upwards
Replace the nozzle if damage is perceived or
considerable wear and tear is discerned.
Contact the distributor
Fill the sprayer with the product to be sprayed
Clean the filter if necessary
Stop the motor and restart the equipment to spray a few
seconds with the lance pointing upwards
Tighten any joint if necessary
Contact the distributor
Change and grease the joints or the filter with joints.
Use the nozzles and work positions recommended in the
nozzle selection tables T.1 and T.2.