6
• UK
Fitting the chimney fan onto the chimney
Step
1
The chimney fan can now be tted into place. Place the
mineral wool mat on top of the chimney (it can be used
with either side facing the fan), and place the fan on
top.
2
Attach the safety wire to the chimney (1). Use the screw
and rawl plug provided in the brickwork of the chimney
or the self-cutting screw if working on a steel chimney.
Then t the wire through the holes in the bottom
section and into the wire clamp
3
Gently tighten the safety wire, and crimp (2) the wire
clamp so that the fan is held safely in place when
opened for servicing or cleaning purposes
4
The isolation switch (extra) should be tted onto the
side of the chimney (3), so it is easily accessible when
servicing the fan. The armoured cable with connecting
cable should be mounted into the underside of the
isolator and up into the switch through the coupling
5
Prior to use check that:
• The fan is closed and the fastening screws/ wing
screws tightened (4)
• The safety wire is taut and the wire clamp crimped (1)
• The coupling nut on the armoured cable is
tightened (2)
• The safety wire is securely attached to the
chimney (5)
• That the user is aware that the fan must always be
switched on whenever the replace or boiler is in use
• The transportation safety bracket has been removed
(RSVG315)
Action
3000127 RSVG DK DE NO SE UK NL FR 20220510