BALTIC LIFEJACKETS – USER'S GUIDE
AUTOMATIC INFLATION MODEL
Inflates automatically within five seconds, upon immersion of the lifejacket. The automatic
lifejacket can also be activated manually by pulling on the activating cord at the lifejacket's
bottom left hand side
2
3
. The mouth inflation tube is also used to deflate the lifejacket. See Deflation.
MANUAL INFLATION MODEL
The manual lifejacket is activated manually by pulling on the activating cord at the lifejacket's bottom
left hand side
. The lifejacket can also be inflated using the mouth inflation tube
2
The mouth inflation tube is also used to deflate the lifejacket. See Deflation.

BEFORE USE

Follow the illustrated instructions on the label by the inflation mechanism.
CHECK THE CO
CYLINDER
1.
2
it is not pierced. Screw the unpierced CO
cylinders are used and must be replaced.
Baltic Elite Automatic Valve
2.
Baltic Elite Automatic Valve
3.
are red, the lifejacket must be inspected and rearmed. Carefully follow the instructions on the
next page or in our rearming kit.
CHECK THE ACTIVATING CORD
4.
accessible without opening the lifejacket.
DEFLATION
The cap on the mouth inflation tube is turned upside down and gently pressed down into the tube
8
. Squeeze out the air. Replace the cap on the mouth inflation tube, in the normal position, be-
fore repacking. NOTE! Do not use any other object than the upside down cap to deflate the lifejacket.
REARMING
BEFORE REARMING
Please note that the following rearming instructions must be followed in order for the product
to function. If you are unsure whether the product is correctly assembled, please contact your
retailer or the manufacturer.
Only use a Baltic rearming kit.
Rearming must be carried out with dry hands, in dry surroundings and without tools.
Place the inflatable lifejacket, back downwards, on a flat surface.
Make sure that the inflatable lifejacket is emptied of all air and that the mouth inflation
tube's cap is in the normal position.
Follow the instructions in this manual and those in the instruction sheet accompanying
the rearming kit.
The product is ready for use only when it has been rearmed according to the instructions.
Follow the following instructions carefully.
. The lifejacket can also be inflated using the mouth inflation tube
Unscrew the CO
4
.
back into place (clockwise) by hand. Pierced CO
2
6
CHECK THAT THE CAPSULE IS IN DATE.
6
, Baltic Elite Manual valve
Check that the activating cord runs freely and is
2
.
cylinder (anticlockwise) and check that
2
7
: If one or both of the indicators
.
3
2
5