FLASHING LIGHT

According to the programmed logic the relay output is activated in an
intermittent manner during the opening and/or closing stages of the
gate.
FLSh
Flashing 1: the relay output is operated intermittently at
2 Hz when the gate is moving, including any pre-flashing
stage prior to departure
FL.PA
Flashing 2: the relay output is operated intermittently at
2 Hz when the gate is moving, during any pre-flashing
stage and with open, paused gate
rEL1
COURTESY LIGHT
According to the programmed logic the relay is closed when the
control unit receives a START command.
CYCL
The relay output is closed when the control unit receives
a START command. When the gate closes the relay
output still remains closed for the set time, then opens.
rEL1
Crt.L
W.L.
Warning light: indicates the real time status of the gate,
the type of flashing indicates the four possible
conditions:
- GATE STOPPED light off
- GATE PAUSED light steadily on
- GATE OPENING the light flashes slowly (2Hz)
- GATE CLOSING the light flashes quickly (4Hz)
FLSh
FL.PA
tiM
The relay output is closed when the control unit receives a
START command and opened after the set timer.
If another START command is received during activation,
the timer is reset.
CYCL
ENGLISH - 19 -