INSTALLATION
The SYNCLUX model can be installed both in the control units with
ADI port (CITY1EVO, CITY2+, PD19, PD20, ETC) and control units
with MUDI interface (KB24, etc.)
In the first case, the module should be connected to the control unit
using the ADI port and also the 24 Vac power supply via the red and
LiGh
tWn
black cables if the
or
For connection to the KB24 control unit, there is no need to connect
the module to the ADI port of the control unit, but the connector of
the MUDI port will be connected to the accessories connected of the
KB24 control unit via the RED BLACK BLUE WHITE wires (FIG 2)
The outputs are programmable with the different functions using the
programming menu of the command control unit:
i.Adi
Command control units with ADI interface
-
Command control units with MUDI interface
m
ATTENTION: installation of the device must be carried
out with the power supply of the command control unit
disconnected.
FASTENING:
If the SYNCLUX module must be used with a CITY digital control unit,
fasten the module inside the container of the control unit using the
two screws supplied (Fig. 1).
If the SYNCLUX module must be used inside a NUUR barrier, fasten
the module on the bracket using one of the two screws supplied
(Fig. 3).
Then, connect the two ADI connectors / ACCESSORIES (SYNCLUX
and command control unit) using the cables supplied (Fig. 1-2).
Power the command control unit: the yellow led on the SYNCLUX
module starts to flash to indicate the device is on.
Proceed with programming of the operating parameters.
(FIG1) functions are used.

ELECTRICAL CONNECTIONS

The device has 4 terminal boards and 2 doors for the interface with
the control units:
TERMINAL BOARDS
M1
g
output relay 1
g
M2
output relay 2
g
M3
output for traffic light and barrier lights
M4
g
output to synchronise two devices (master and slave)
PORTS:
ADI
g
ADI interface
MUDI
g
MUDI interface
1
GND
2
M4
M1
LED
The device has 4 signalling leds:
FUNCTION: yellow led that flashes when SNCLUX is on
SYNCRO: in the event of synchronised installation, it flashes green
when the two MASTER and SLAVE devices are working correctly. It
turns fixed red when the two MASTER and SLAVE devices do not
communicate.
CH1: red led that switches on when the relay 1 output is enabled
CH2: red led that switches on when the relay 2 output is enabled
FUNCTION
SYNCRO
CH1
CH2
M3
M2
ENGLISH - 15 -