7-day - each day can be programmed with different times and
temperatures.
5/2 day - one set of times & temperatures for weekdays, and
another set for weekends.
Optimum start control - function which switches the heating on
earlier than the Event 1 programmed time to ensure the required
temperature is achieved by the set time.
Chrono-proportional control - energy saving feature which
fi res the boiler at regular intervals to maintain a set temperature,
achieving a constant ambient environment for the user.
For a full explanation of all advanced features please visit
our website www.danfoss-randall.co.uk or call 01234 364621
to obtain a copy of our Advanced Features Guide.

Setting Optimum Start Control

Set Sw2 to OSC ON (see
J
DIL settings page 4)
Select OPTIMISER CURVE
J
in programming mode
A - Event 1 Set Point
B - Deviation from Set Point
C - Switch On Time prior to
Event
D - Optimiser Curve Setting

TP7000 Wiring (not RF models)

2
1
COM
ON
M models only
L
ELECTRONICS
3
4
5
OFF
N
A
-1˚C
B
-2˚C
-3˚C
-4˚C
120
90
min.
min.
6
7
REMOTE
SENSOR
'A' models
only
D
30
60
Event 1
min.
min.
time (0)
C