Specifications

Installation Requirements
The Coffee System can be installed in a standard or flush
inset application. The sides of the cabinet opening must
be adequate to support installation of the mounting slides.
Refer to the illustration below.
Specify one opening if a Coffee System is installed above a
Cup Warming Drawer.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, the face trim overlaps stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum 3 mm reveal is
required on all sides. Each corner of the opening must be
exactly 90° to maintain consistent reveals.
BASE SUPPORT
Coffee System
TRIM OVERLAP
Top
Bottom
Sides
19 mm
TYPICAL
356
mm
76 mm
Slide support dimensions
4 | English
Electrical Requirements
Installation must comply with all applicable electrical
codes and be properly grounded (earthed).
Locate the electrical supply as shown in the following
illustrations. A separate circuit servicing only this appliance
is required. A ground fault circuit interrupter (GFCI) is not
recommended and may cause interruption of operation.
REQUIRED POWER SUPPLY
Electrical Supply
220-240 VAC, 50/60 Hz
Service
Receptacle
grounding-type (earthed)
Power Cord
IMPORTANT NOTE: Connection of this appliance should
be through a fused connection unit or a suitable isolator,
which complies with national and local safety regulations.
45 kg
The on/off switch should be easily accessible after the
appliance has been installed. If the switch is not accessible
after installation (depending on country) an additional
means of disconnection must be provided for all poles
5 mm
of the power supply. When switched off there must be an
0 mm
all-pole contact gap of 3 mm in the isolator switch. This
3 mm contact disconnect gap must apply to any isolator
18 mm
switch, fuses and/or relays according to EN60335.
Coffee System
STANDARD INSTALLATION
1350 W
1.8 m
449 mm
SLIDE
OPENING
SUPPORT
HEIGHT
SIDE VIEW
NOTE: 610 mm model and model with 762 mm trim require the same opening dimensions.
OPENING WIDTH
610 mm Model
762 mm Model
548 mm
OPENING
SLIDE
DEPTH
SUPPORT
TOP VIEW
E
W
OPENING WIDTH
FRONT VIEW
W
562 mm