Technical specifications
Refrigerant, cubic capacity and further
technical specifications can be found on
the rating plate.
~ "Getting to know your appliance"
on page 21
Installing the appliance
Installation location
The more refrigerant an appliance
contains, the larger the room must be
in which the appliance is situated.
Leaking refrigerant can form
a flammable gas-air mixture in rooms
which are too small.
The room must be at least 1 m³ per 8 g
of refrigerant. The amount of refrigerant
in your appliance is indicated
on the rating plate inside the appliance.
~ "Getting to know your appliance"
on page 21
The weight of the appliance may be up
to 65 kg depending on the model.
Permitted room temperature
The permitted room temperature
depends on the climatic class of the
appliance.
Information on the climatic class can be
found on the rating plate.
~ "Getting to know your appliance"
on page 21
Installation and connection en
Climatic cate-
Permitted room temperature
gory
+10 °C ... 32 °C
SN
N
+16 °C ... 32 °C
ST
+16 °C ... 38 °C
+16 °C ... 43 °C
T
The appliance is fully functional within
the permitted room temperature.
If an appliance of climatic class SN is
operated at colder room temperatures,
the appliance will not be damaged up to
a room temperature of +5 °C.
Niche depth
A niche depth of 56 cm is required
for the appliance.