10.

Maintenance and care

The complete jaw mechanism must be maintained regularly.
10.1

To clean or change the jaws

Disconnect the tool from the compressed air supply.
Unscrew steel head sleeve and clean inside if necessary.
Use 17 mm and 14 mm open-ended spanners to release jaw housing from lock activator,
clean or replace if worn.
Remove jaws, clean and oil sliding surfaces; replace if worn.
Check jaw pusher for wear; replace if necessary.
Reassemble the jaw mechanism in reverse order; screw together; tighten.
10.2

To top up oil

Unscrew steel head sleeve and jaw housing.
With the trigger button pressed, disconnect the riveting tool from the compressed air
supply (air piston in upper end position).
Undo oil refill screw plug and push lock activator into the rear end position by hand.
With supplied refill bottle – fit filler piece deep into the tool head – top up oil free of bubbles.
Moderately tighten the refill screw plug with seal.
Connect the riveting tool to the compressed air supply.
Drain off overfilled oil by releasing the refill screw plug and then moderately tighten again.
Fit jaw housing and, with the trigger button pressed, fit and tighten steel head sleeve.
10.3

Storage

Store the riveting tool in a dry place where there is no danger of frost.