Features of the Dynafor™ Industrial range
Model
EN
SWL
Safety coefficient
Accuracy
Resolution
Measurement
frequency
Max. display
Height of digits
Display unit
Conversion factor
Battery life
Net weight of sensor
IP rating
Operating temperature
Body material
Type of battery
Dimensions (figure 3)
A
B
C
D
E
F
G
H
In case of difficulties or special uses, please contact Tractel
The product described in this manual complies with the following:
European standards
Machinery Directive 2006/42/EC
Reference of EMC standards: 2004/108/EC
International Standard
IEC 61326-1 Ed.2: 2012
IEC 61311: 2007
12
Industrial 1
Industrial 3.2
Unit
t
1
± %
± kg
3
kg
1
Hz
%
mm
h
kg
0.75
°C
191
164
22
83.5
mm
22
19.8
36.4
37.6
11. Regulations and standards
Industrial 6.3
3.2
6.3
>4
0.3% MR
9.6
18.9
2
5
3 Hz - 32 Hz in peak load mode
110% of SWL
18
kg/daN/lbs
1 kg = 0.98083 daN = 2.20462 lbs
250
0.93
1.44
IP 64
-20°C to +50°C
Aluminium
2x AAA
191
236
164
184
22
28
99.5
121.5
22
22
19.8
19.8
36.4
36.4
44.8
54.7
®
.
Industrial 12.5
Industrial 20
12.5
20
37.5
60
10
20
3.22
5.1
277
342
226
264
42
54
120.5
147
45
45
40.5
40.5
59.4
59.4
60
73.5