Operating Instructions SATA filter 500
10. Maintenance
• Filters can only be maintained and serviced when depressurised!
• Sintered filter [A]/Art. No. 22160, filter housings [1-9], [1-11],
[1-12] and special seal [1-16] must be cleaned at the latest after 6
months; replace sintered filter if necessary!
• Replace the fine filter cartridge [B]/Art. No. 1097999 at the latest
after 6 months!
• Replace the activated charcoal cartridge [C]/Art. No. 1098004 at
the latest after 6 months!
• When the compressed air is heavily contaminated, the filter
cartridges have to be exchanged in shorter intervals!
• Saturated filter cartridges may cause malfunctions during paint
jobs. Furthermore, the use of air-fed breathing protection equip-
ment could be harmful, causing permanent health damage and
even death!
• Always make sure that the filter housings are fitted correct-
ly! Filter housings are only correctly fitted after an audible "click"
and when both droplet symbols are in line !
Notice!
Please observe local regulations for the disposal of filter cartridges!
11. Troubleshooting
Malfunction
Pressure cannot be
properly adjusted
Warning! Attention!
Cause
Insufficient inlet pres-
sure
Pressure regulation
valve is defective
Corrective action
Increase inlet pressure
Replace membranes
EN
83