Operating Instructions SATA filter 500
EN
14. Slowly open upstream shut-off tap (not included in delivery)
7.3. Change air flow for SATA filter 584 from right
to left
1. Depressurise filter (close shut-off tap)
2. Remove filter housings [4-1] by turning clockwise
3. Loosen cover unit screws and remove unit [4-2]
4. Loosen screws of wall-mounting kit and remove wall-mounting kit [4-
3]
(Caution! Filter heads [1-15] loose)
5. Loosen and remove [4-4] dummy plug
6. Heat pressure gauge [4-5] with hot air gun to
soften glued bond. Pressure gauge can be unscrewed by hand.
(Caution! Only unscrew pressure gauge by hand)
7. Glue pressure gauge to other side with Loctite 276 and
align the display [4-6] (Caution! Glue is hard after approx. 5 minutes)
8. Screw dummy plug [4-7] to block
9. Fasten wall-mounting kit with 8 screws [4-8]
(Caution! Push filter heads [1-15] together)
10. Fix cover unit with 3 screws [4-9]
(Caution! Note orientation)
11. Insert filter housings [4-10] and mount on the filter
(Caution! Filter housings are only correctly fitted after an audible
"click" and when
both droplet symbols are in line !)
12. Slowly open upstream shut-off tap
(not included in delivery)
80