6. Commissioning
The tasks described in this section may only be
carried out by a qualified electrician.
6.1
Configure
In the top section of the housing, there are 4 configuration
switches and 2 rotary encoder switches, with which the
device can be configured.
1
2
S4
3
4
S3
S2
Fig. 9: Configure
4 x configuration switches S4
The configuration switches S4.3 and S4.4 have no
function.
Blue rotary encoder switch S3
White rotary encoder switch S2
After the configuration is complete, a restart is
required.
There is another rotary coding switch in the middle of the
ECU. This has no function.
6.1.1
Setting the tone
The tone output during startup can be set using the con-
figuration switch S4.1.
Î "Fig. 9: Configure"
Position
Configuration switch S4.1 = 1 (ON)
Configuration switch S4.1 = 0 (OFF)
(default setting)
f Set as desired.
6.1.2 Set Colour Scheme
The colour of the symbols "Standby" and "Charging" on
the LED information panel can be set using the configura-
tion switch S4.2.
Î "Fig. 9: Configure"
Position
Configuration switch S4.2 = 1
(ON)
Configuration switch S4.2 = 0
(OFF) (default setting)
f Set as desired.
6.1.3 Set Operation Mode
The operating modes can be set using the rotary encoder
switch. To set the operating mode, a flat-tip screwdriver is
required.
Î "Fig. 9: Configure"
Î "3.4 Operating modes"
Blue rotary encoder switch S3: Maximum charging current
Position(s)
Maximum charging current
0, 1, 2 and 3
16 A
4
13 A
5
10 A
6
8 A
7
6 A
The positions "8" and "9" are not populated. If
the blue rotary encoder switch S3 is set to "8" or
"9", a fault is displayed.
Tone
Tone off
Tone on
Colour Scheme
LED "Standby" = green
LED "Charging" = blue
LED "Standby" = blue
LED "Charging" = green
15