used as prescribed it is still impossible to elimina-
te certain residual risk factors. The following ha-
zards may arise in connection with the machine's
construction and layout:
•
Contact with the grinding wheel where it is not
covered.
•
Catapulting of parts from out of damaged
grinding wheels.
•
Catapulting of workpieces and parts of work-
pieces.
•
Damage to hearing if essential ear-muffs are
not used.
The equipment is allowed to be used only for its
prescribed purpose. Any other use is deemed to
be a case of misuse. The user/operator and not
the manufacturer will be liable for any damage or
injuries of any kind resulting from such misuse.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
equipment is used in commercial, trade or indust-
rial businesses or for equivalent purposes.
4. Technical data
Mains voltage: ........................ 220-240 V ~ 50 Hz
Power rating: ............. 110 W S1 | 150 W S6 15%
Idle speed n
: ......................................2980 min
0
Grinding/sanding wheel ø max.: ............. 157 mm
Grinding/sanding wheel ø min.: .............. 127 mm
Grinding/sanding wheel ø: ...................... 150 mm
Grinding/sanding wheel thickness: ........... 16 mm
Grinding/sanding wheel hole ø: ................ 32 mm
Peripheral speed: ...................................23.4 m/s
Grinding/sanding wheel grit size (coarse): .... K36
Grinding/sanding wheel grit size (fi ne): .......... K60
Protection class : ................................................. I
Weight: ............................................. approx. 6 kg
Operating mode S6 15%: Continuous operation
with idling (cycle time 10 minutes). To ensure that
the motor does not become excessively hot, it
may only be operated for 15% of the cycle at the
specifi ed rating and must then be allowed to idle
for 85% of the cycle.
Anl_TC-BG_150_SPK9.indb 20
Anl_TC-BG_150_SPK9.indb 20
GB
Danger!
Noise
The noise emission values were measured in ac-
cordance with EN 62841.
Operation
L
sound pressure level ..................... 82.3 dB(A)
pA
K
uncertainty ........................................ 3 dB(A)
pA
L
sound power level ....................... 95.3 dB(A)
WA
K
uncertainty ........................................ 3 dB(A)
WA
Wear ear-muff s.
The impact of noise can cause damage to hea-
ring.
The stated noise emission values were measured
in accordance with a set of standardized criteria
and can be used to compare one power tool with
another.
The stated noise emission values can also be
used to make an initial assessment of exposure.
Warning:
The noise emission levels may vary from the level
specifi ed during actual use, depending on the
way in which the power tool is used, especially
the type of workpiece it is used for.
Keep the noise emissions and vibrations to a
-1
minimum.
•
Only use appliances which are in perfect wor-
king order.
•
Service and clean the appliance regularly.
•
Adapt your working style to suit the appliance.
•
Do not overload the appliance.
•
Have the appliance serviced whenever ne-
cessary.
•
Switch the appliance off when it is not in use.
Limit the operating time!
All stages of the operating cycle must be conside-
red (for example, times in which the electric tools
are switched off and times in which the tool is
switched on but operates without load).
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
- 20 -
27.04.2023 14:41:13
27.04.2023 14:41:13