Download Inhoudsopgave Inhoud Print deze pagina

EINHELL 41.525.60 Originele Handleiding pagina 26

Verberg thumbnails Zie ook voor 41.525.60:
Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 76
10. Troubleshooting
Fault
Engine does not
start
Generator has too
little or no
voltage
The battery does
not charge up
Starter does not
turn
Mögliche Ursache
Automatic oil cut-out has not respon-
ded
Spark plug fouled
No fuel
Controller or capacitor defective
Overcurrent circuit-breaker has
triggered
Air fi lter dirty
Poor contact to the battery
Battery defective
Defective fuse (Fig. 16a/16b)
Battery discharged
Battery not connected
GB
Check oil level, top up engine oil
Clean or replace spark plug (electro-
de spacing 0.6 mm)
Refuel / have the petrol cock checked
Contact your dealer
Actuate the circuit-breaker and
reduce the consumers
Clean or replace the fi lter
Clean the contacts
Have the battery checked by an ex-
pert and replace it if necessary
Check the function of the equipment
using a diff erent battery; replace the
fuse
Charge the battery
Connect the battery
- 26 -
Behebung

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Tc-pg 5500 wd11016

Inhoudsopgave