 You must open the cover of the supply tank before operating the oil
pump's hand lever/pushbutton.
 Check the oil volume: there must be an adequate volume of oil in the
supply tank. The oil level must be visible in the strainer.
 The meter must be operational, i.e. the turbine wheel must be turning.
 Actuate the oil pump by hand as shown in Table 9. Pull the hand lever
evenly as far as possible or press the pushbutton down as far as possible.
One actuation cycle corresponds to one stroke of the pump's piston.
 After actuation, you must reseal the supply tank tightly.
Meter size:
DN 50
DN 80/100
DN 150
Oil type:
Shell Catenex T 121
Klüber ISOFLEX PDP 38
Table 9 | Maintenance instructions
4.1 Cleaning
WARNING!
Danger of electrostatic discharge – only use a damp cloth to clean.
DANGER!
 Danger of explosion resulting from electrostatic discharge.
 There is a risk of explosion if the plastic cover of the index is
cleaned with a dry cloth.
 It is forbidden to use aggressive chemical cleaning agents or
solvents for cleaning.
 The plastic parts may only be cleaned with water.
73018696g
© Elster GmbH | All rights reserved. Subject to modification
Maintenance instructions
Number of strokes:
Oil pump with lever
(Premium Line)
2
4
6
Oil types
Pushbutton oil pump
(Standard Line)
4
8
12
Operating temperature range:
-10°C to +70°C
-25°C to +70°C