3.4 Requirements to be met before installation
 Remove sealing caps and foils.
 Check the meter and accessories for signs of transport damage.
 Check that the turbine moves easily by generating a gentle air current.
 Ensure that you have all the tools you require available.
 Check that all the accessories are present (e.g. plug connectors, oil for
initial filling).
 Seals which are suitable for your operating medium (see Table 4 for
examples). Please also check whether you must comply with other
standards, e.g. DIN EN 1591, Parts 1 – 4.
Table 4 | Suitable seals and gaskets
 Hexagon screws and nuts for flanges to DIN EN 1092-1
Material / Strength class
Screw
5.6
8.8
CK 35
25CrMo4
Table 5 | Suitable screws
 Stud bolts with continuous thread for flanges to ASME B 16.5
Material / Strength class
Screw
A193 B6
A193 B7
Table 6 | Suitable stud bolts
 Other equivalent materials may also be used.
20
DN
d1 [mm]
50
80
100
150
Nut
5
8
CK 35
25CrMo4
Nut
A194 Gr. 6
A194 Gr. 2H
up to 100 bar / -25°C
73018696g
© Elster GmbH | All rights reserved. Subject to modification
The following seals and
gaskets, among others, are
62
suitable:
100
- flat seals
125
- spiral-wound gaskets
178
- grooved seals and gaskets
Operating limits
up to 40 bar
down to -10°C
up to 100 bar
down to -10°C
up to 100 bar
down to -25°C
Operating limits
up to 100 bar / 0°C
Standards
DIN ISO 4014
DIN ISO 4032
DIN 2510
EN 10269
Standards
ASME B 1.1