Functional description of the NTC temperature control: If the system temperature
of the electronical control exceeds 103°C, the upper heating element will shut off
temporary by default to avoid over heating of the electronical parts. After a short
time the heating element will switch on automatically again. The self-controlled
shut off of the heater will take place only, if the heat dissipation inside the device is
inappropriate, if the heat radiation is interfered or if the ambience temperetaure is
way too high. Apart from that the NTC temperature control supports energy safings,
if the ambient temperatures are too high and the highest heating level of the heating
unit is not necessary.
Functional description of the latching temperature limiter: If the NTC tempera-
ture control is not working against expectations, the latching temperature limiter
will shut down the lower heating element permanently, until the heater is shut off
totally by hand. After cooling down (warm to the touch) and fixing the inappropriate
heat dissipation inside the device and/or the interferred heat radiation the heater
can be switched on again. If the lower heating element shuts down once more, a
system malfunction or a heat dissipation inside the device or an interference of the
heat radiation or an error in the electrical installation may be the reason. If a system
malfunction inside the device causes the shut down, the heater must be repaired by
a professional technician; please contact your dealer immediately. If a wrong cable
connection causes the shut down, this has to be checked and fixed through a profes-
sional electrician on the spot.
Installation and connecting regulations with tested and approved luster terminals are
part of the delivered equipment.
13. The radiant heater must not be installed directly below a power source/socket.
The sides of the unit must be at least 20 cm from the nearest power source. Sockets/
power sources must be freely accessible at all times and comply with the following
specifications: 220–240 V AC ~, 50/60 Hz, 16 A with 16 A fuse. No other loads may be
connected to this power source.
14. The radiant heater must not be installed in rooms where there is high humidi-
ty (bathroom, spa, pool etc.) in close vicinity to bathtubes, showers or pools. The
distance to the bathtub or shower must be at least 100 cm and the distance to the
pool at least 200 cm. A person standing in the bathtube, shower or pool should never
reach the switch or controller of the heater. If the HEATSCOPE® is installed in such
an environment with high humidity, the switches or other operating components