Download Print deze pagina

Kärcher IVM 60/36-3 H ACD Oorspronkelijke Gebruiksaanwijzing pagina 33

Advertenties

7. Check the seating of the filter and cor-
rect if necessary.
8. Replace the main filter (see chapter Re-
placing the main filter).
Escaping dust when vacuuming
1. Check the seating of the filter and cor-
rect if necessary.
2. Dedust the main filter (see chapter De-
dusting the main filter).
3. Replace the main filter (see chapter Re-
placing the main filter).
Disposal
At the end of its service life, the device is to
be disposed of in accordance with statutory
regulations.
Warranty
The warranty conditions issued by our rele-
vant sales company apply in all countries.
We shall remedy possible malfunctions on
your appliance within the warranty period
free of cost, provided that a material or
manufacturing flaw is the cause. In a war-
ranty case, please contact your dealer (with
the purchase receipt) or the next author-
ised customer service site.
(See overleaf for the address)
Further warranty information (if available)
can be found in the service area of your lo-
cal Kärcher website under "Downloads".
Technical data
Electrical connection
Mains voltage
Phase
Power frequency
Nominal power
Maximum power
Protection type
Protection class
Maximum permissible
mains grid impedance
V
220-
240
~
1
Hz
50-60
W
3150
W
3600
IPX4
I*
Ω
0.195+
j0.122
English
Dimensions and weights
Typical operating weight
Length x width x height
Effective main filter area
Effective H-filter area
Ambient conditions
Ambient temperature
Storage temperature
Device performance data
Container capacity
Vacuum (with pressure re-
lief valve)
Max. volume flow with
suction hose DN70, L=3 m
Max. volume flow with
suction hose DN50, L=3 m
Max. volume flow with
suction hose DN40, L=3 m
Max. volume flow with
suction hose DN70, L=5 m
Max. volume flow with
suction hose DN50, L=5 m
Max. volume flow with
suction hose DN40, L=5 m
Suction hose connection
Nominal width of the suc-
tion hose
Main filter order number
Main filter order number
Determined values in acc. with EN
60335-2-69
Hand-arm vibration value m/s
K uncertainty
Sound pressure level L
Uncertainty K
pA
kg
73
mm
1020 x
680 x
1670
2
m
2
2
m
3.5
°C
-10-40
°C
-10-40
l
60
kPa
20.1
3
m
/h
420
3
m
/h
367
3
m
/h
270
3
m
/h
412
3
m
/h
305
3
m
/h
237
DN70
DN40/
50/70
9.990-
493.0
9.993-
006.0
2
<2.5
2
m/s
0.2
dB(A) 79
pA
dB(A) 2
33

Advertenties

loading