INSTALLATION
SAFETY
7.
Safety
7.1
Country-specifi c safety information
Observe these installation instructions during installation.
We guarantee trouble-free function and operational reliability
only if the original accessories and spare parts intended for the
appliance are used.
7.2
Instructions, standards and regulations
Risk of damage
!
Observe the type plate. The specifi ed voltage must
match the mains voltage.
Note
Observe the Building and Garage Regulations
[or local regulations].
Danger to life through electrocution!
All electrical connection and installation work must
be carried out in accordance with VDE regulations
(DIN VDE 0100) [or local regulations], the rules
of your local power supply utility, and relevant
national and local regulations.
Danger to life through electrocution!
Never use a permanently installed connecting cable.
The appliance must be able to be separated
from the mains power supply by an isolator that
disconnects all poles with at least 3 mm contact
separation.
Fixing information
!
Only fi t the appliance to a vertical wall that is
temperature-resistant to at least 85 °C.
Maintain minimum clearances to adjacent surfaces.
Never install the appliance directly below a
wall socket.
Important information
Only remove appliance and accessory packaging
at the installation location; look out for the
separate pack.
When unpacking, ensure that no accessory parts
are left in the packaging.
Important information
!
When installing the boiler in rooms with a bath and/
or shower, observe the safety zone according to
VDE 0100, part 701, in accordance with the details
on the appliance type plate.
Danger to life through electrocution!
Install the appliance in such a way that control
equipment cannot be touched by a person in the
bath or shower.
12
|CBS 20 S
8.
Installation
If you are replacing one of our CK appliances, the holes available
to secure the appliance can be used.
8.1
Appliance installation
To secure the appliance, proceed as follows:
»
Secure the supplied mounting bracket horizontally on the
installation wall with the tab cut-out towards the top. Use
suitable fi xing materials (screws, rawl plugs) for this, subject
to the type of wall. The horizontal and vertical slots enable an
adjustment in case the fi xing holes are not quite where they
should be.
»
Hook the appliance with the upper vertical recesses of the back
panel into the mounting bracket.
Wall fi xing
1
Mounting bracket
»
Secure the appliance and mounting bracket with the fi xing
screw.
Securing
2
Fixing screw
1
2
www.stiebel-eltron.com