22
Standard (120V/60Hz) - Gas Oven Heating Values & Orifice Sizes
Heating Values
Oven Model
All Fuels
BTU/HR
Inches
1832
56,000
0.136
71,000
2336
0.152
71,000
2440
0.152
88,000
3240
0.170
122,000
3240-HP
0.196
3255
115,000
0.187
130,000
3255-HP
0.209
190,000
3270
0.176
240,000
3270-HP
0.196
3855
115,000
0.196
148,000
3855-HP
0.218
198,000
3870
0.181
240,000
3870-HP
0.196
World (230V/50Hz) - Gas Oven Heating Values & Orifice Sizes
Heating Values
Natural
Oven Model
G20
KW/HR MJ/HR KW/HR KW/HR KW/HR MJ/HR
1832
16.41
59.08
13.18
2336
20.80
74.88
16.99
2440
20.80
74.88
16.99
3240
25.79
92.85
20.80
3240-HP
35.75
128.70
27.98
3255
33.70
121.32
26.08
3255-HP
38.10
137.16
33.11
3270
55.68
200.45
46.30
3270-HP
70.30
253.09
55.00
3855
33.00
118.80
30.00
3855-HP
43.37
156.14
38.00
3870
58.03
208.91
54.22
3870-HP
70.30
253.09
55.00
De HP achter Oven Model staat voor High Performance.
NOTA
De vermelde BTU-metingen zijn maximumwaarden die bereikt kunnen worden
tijdens het klimmen naar de gewenste temperatuur. Zodra het instelpunt is bereikt,
NOTA
zal de BTU/HR dalen. De metingen zullen variëren als de capaciteit van de oven
tijdens het gebruik verandert.
Standard, World, and Australia
Oven
Models
Natural Gas
W/C
mbar
kPa
All
6-14
15-35
1.50-3.50
Technische Hulp US: 888-443-2751
Ovenvereisten
Alle op deze pagina waarden zijn per elke oven
Orifice Sizes
NAT
LP
MM
Inches
MM
3.45
0.084
2.13
3.86
0.098
2.49
3.86
0.098
2.49
4.32
0.104
2.64
4.98
0.125
3.18
4.75
0.120
3.05
5.31
0.130
3.30
4.47
0.111
2.82
4.98
0.125
3.18
4.98
0.123
3.12
5.54
0.134
3.40
4.60
0.111
2.82
4.98
0.125
3.18
Propane
Butane
G31
G25
G30
18.50
16.41
59.08
25.00
20.80
74.88
25.00
20.80
74.88
25.79
23.44
84.39
38.24
35.75
128.70
39.56
35.16
126.58
39.85
35.46
127.66
58.03
55.68
200.45
76.78
70.30
253.09
38.10
33.70
121.32
43.37
39.85
143.46
58.03
54.22
195.20
76.20
70.30
253.09
Gas Oven Fuel Pressure Requirements
Inlet Pressure Range
LP Gas
W/C
mbar
kPa
11.5-14
27.5-35
2.75-3.50
Gas Oven Bypass Orifice Sizes
Gas Types
Propane
Australia & New Zealand (230V/50Hz) - Gas Oven Heating Values & Orifice Sizes
Heating Values
Oven Model
NAT
KW/HR MJ/HR KW/HR MJ/HR
1832
16.41
59.08
2336
20.80
74.88
2440
20.80
74.88
3240
25.79
92.84
3240-HP
35.75
128.70
3255
33.70
121.32
3255-HP
38.10
137.16
3270
55.68
200.45
3270-HP
70.30
253.08
3855
33.00
118.80
3855-HP
43.37
156.13
3870
58.03
208.91
3870-HP
70.30
253.08
Korea (220V/60Hz) - Gas Oven
Orifice Sizes
Heating Values & Orifice Sizes
NAT
LP
Oven Model
MM
MM
3.45
2.13
1832
3.86
2.49
2336
3.86
2.49
2440
4.32
2.64
3240
4.98
3.18
3240-HP
4.75
3.05
3255
5.31
3.30
3255-HP
4.47
2.82
3270
4.98
3.18
3270-HP
4.98
3.12
3855
5.54
3.40
3855-HP
4.60
2.82
3870
4.98
3.18
3870-HP
Korea
Natural Gas
LP Gas
kPa
kPa
W/C mbar kPa W/C mbar kPa
1.50-2.50
2.30-3.30
Orifice Sizes (in.)
0.046
Technische Hulp INTL: 316-943-2751
Orifice Sizes
LP
NAT
LP
MM
MM
16.41
59.08
3.45
2.13
20.80
74.88
3.86
2.49
20.80
74.88
3.86
2.49
23.44
84.38
4.32
2.64
35.75
128.70
4.98
3.18
35.16
126.58
4.75
3.05
35.46
127.66
5.31
3.30
55.68
200.45
4.47
2.82
70.30
253.08
4.98
3.18
33.70
121.32
4.98
3.12
39.85
143.46
5.54
3.40
54.22
195.19
4.60
2.82
70.30
253.08
4.98
3.18
Heating Values
Orifice Sizes
NAT
LP
NAT
LP
KW/HR KW/HR
MM
MM
16.41
16.41
3.45
2.13
20.80
20.80
3.86
2.49
20.80
20.80
3.86
2.49
25.79
23.44
4.32
2.64
35.75
35.75
4.98
3.18
33.70
35.16
4.75
3.05
38.10
35.46
5.31
3.30
55.68
55.68
4.47
2.82
70.30
70.30
4.98
3.18
33.00
33.70
4.98
3.12
43.37
39.85
5.54
3.40
58.03
54.22
4.60
2.82
70.30
70.30
4.98
3.18
Manifold Pressure
Natural Gas
LP Gas
3.5
8.75 0.875
10
25
2.5