10. Installer information

The LED light is off -
Function
Standby
Running
Ambient sensor
fault
High pressure protection
Low pressure protection
Defective water pressure
sensor
Protection against low
ambient temperature

10.1 Dimensions

Dimension in mm
Models
A
B
C
D
E
F
G
H
MV-1086-11-2018 . © All rights reserved Swim & Fun Scandinavia ApS
The LED light is on

LED Light

LD1 LD2 LD3 LD4
LD1 LD2 LD3 LD4
LD1 LD2 LD3 LD4
LD1 LD2 LD3 LD4
LD1 LD2 LD3 LD4
LD1 LD2 LD3 LD4
LD1 LD2 LD3 LD4
1086
273
423
260
293
747
210
83
470
Reason
Open sensor or
short circuit
Too much refrigerant.
Insufficient
air flow.
Insufficient refrigerant.
Insufficient water flow.
Blocked/jammed filter or
blocked/jammed capillary
tube
No water/small amount of
water in the water system
The ambient temperature is
below 7
C
o
Solution
Check or
change the sensor
Discharge excess refrig-
erant from the HP gas
system.
Clean the air exchanger
Check to see if there is a
gas leak,
refill the refrigerant.
Clean the air exchanger.
Replace the filter or capil-
lary
Check the water flow.
Check if the pool pump is
running or not.
Once the ambient temper-
ature is over 8
C, the unit
o
will run again.
77