Mode
Comfort
Reduced
Frost protection
Stop
Comfort -1°C (*)
2°C setback
(*) : Orders sent by EDF
Maintenance
It is preferable to use a soft dry cloth to clean the housing.
Never use abrasives.
• Towel radiator equipped with Turbo option:
Use a vacuum cleaner to clean the intake and outlet
screens.
Specifications
Accuracy of temperature measuring
Accuracy of temperature setting
Temperature range
Electrical Protection
Controlled power (receiver)
Batteries (transmitter)
Transmission distance (thermostat to receiver)
Operating temperature (transmitter)
Storage temperature (transmitter)
6
Signals via the pilot wire
4'57" 3"
4'57"
3"
4'57" 3"
4'57"
3"
4'57" 3"
4'57"
3"
4'57" 3"
4'57"
3"
4'57" 3"
4'57"
3"
4'53" 7"
4'53"
7"
4'53" 7"
4'53"
7"
4'53" 7"
4'53"
7"
4'53" 7"
4'53"
7"
4'53" 7"
4'53"
7"
4'57" 3"
4'57"
3"
4'53" 7"
4'53"
7"
Infrared Thermostat Transmitter with Digital Display - Instructions PPLIMP10314/Bd of 03/03/2011
Results / "A" or "F" LED
Depends on transmitter setting in comfort mode.
Pause:
Solid green
Heating: Solid red
Depends on transmitter setting in comfort mode -3.5°C.
Pause:
Flashing green
Heating: Solid red
Room temperature is maintained at 7°C +/- 3°C
Pause:
Off with flashing green light
Heating: Solid red
Device turned off instantly.
LED off
Depends on transmitter setting in comfort mode -1°C.
Pause: LED green with fade-out flash
Heating:
Solid red
Depends on transmitter setting in comfort mode -2°C
Pause:
LED green with two fade-out flashes
Heating:
Solid red
When the cleaning dust filter light (D) is on, the Boost
function becomes inoperative.
Remove the filter from the rear of the Turbo and clean
with a vacuum cleaner with a brush. Put the filter back
in place.
Press and hold the «H»
and return to operating mode.
0.1°C
0.5°C
In comfort and reduced: 10°C-30 °C
In frost protection: 5°C – 10°C
Receiver: Class II - IP44
Turbo: Class II - IP24
Transmitter: Class II - IP30
12A / 250V 16A RELAY
2x AA/LR61.5V alkaline batteries
10m in all directions
0°C to 50 °C
-10°C to 50°C
button to initialize the Turbo