Commissioning

ROOM SENSOR
The room unit RMU S40 contains a room sensor with the
same function as the room sensor (BT50) accompanying
the main product.
This makes it possible to select which room sensor the main
product will use for displaying and control of the room
temperature, where applicable.
NOTE!
In the main product's menu 1.3.3 - "Room units",
you can choose the room sensor that you want to
use for inspection control.
The room unit has up to four functions:
1.
Show current room temperature in the heat pump/in-
door module display.
2.
Provides the option of changing the room temperature.
3. Provides the option of changing/stabilising the room
temperature.
4. Provides the option of presenting and controlling the
humidity.
The room temperature sensor is installed in a neutral location
where the set temperature is required. A suitable location
might be, for example, on a free inner wall in a hall approx.
1.5 m above the floor. It is important that the room temper-
ature sensor is not prevented from measuring the correct
room temperature, for example by being located in a recess,
between shelves, behind a curtain, above or close to a heat
source, in a draught from an external door or in direct sun-
light. Closed radiator thermostats can also cause problems.
Control of the room unit is activated in menu 1.3.3 - "Room
units".
NOTE!
Closed floor/radiator thermostats affect the indoor
temperature.

SETTINGS IN THE MAIN PRODUCT

Adjust the basic settings for each RMU S40 in the main
product. In order to determine more easily the room in which
RMU S40 is located, you can give each room unit a unique
name.
NOTE!
The main product's software must be the latest
version.
NIBE RMU S40 | EN

CLIMATE SYSTEMS AND ZONES

Multiple climate systems are used when different supply
temperatures are required for different parts of the system,
for example when both underfloor heating and radiators are
fitted in a property.
A climate system can be divided up into several zones, which
can be allocated one or more sensors or other accessories.
A zone could be a specific room or part of larger premises.
2
2
1
1
This example shows a property with two climate systems (1
and 2, two separate floor levels) divided into four zones (1-4,
four different rooms). With a controlled radiator valve (SRV
10), the temperature can be controlled individually for a
zone.
REPEATER RPP 10
If the communication is weak between the main product
and an accessory in a zone, a repeater (RPP 10) may need
to be installed to amplify the signal between the zones.
1
2
3
Main product
3
4
12
9
3
6
1
2
3
Repeater
23