TROUBLESHOOTING
COMMUNICATION ERROR
RMU S40 has lost contact with the main product.
Wireless connection
Check that the distance between the main product and
RMU S40 is not too great.
If the communication is weak between the main product
and an accessory in a zone, a repeater (RPP 10) may need
to be installed to amplify the signal between the zones.
Wired connection
Check that the cable is correctly connected between
RMU S40 and the main product.
Check that the addresses in the room unit's "Installation"
menu and the main product's 7.2.1 menu correspond.
THE DISPLAY IS OFF
No information is visible on the display.
Check that the screensaver is active by pressing the
screen.
Check that the On/Off button is set to On.
Check that the cable is correctly connected between
RMU S40 and the main product.
If RMU S40 is set to "Night mode", the display is off. (See
Menu 1 – Night mode.)