Download Inhoudsopgave Inhoud Print deze pagina

Nibe RMU S40 Installatiehandleiding pagina 28

Verberg thumbnails Zie ook voor RMU S40:
Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 73
NOTE!
An increase in the room temperature can be
slowed by the thermostats for the radiators or
under floor heating. Therefore, open the thermo-
stats fully, except in those rooms where a cooler
temperature is required, e.g. bedrooms.
TIP!
If the room temperature is constantly too low/high,
you increase/decrease the value by one step in
menu 1.1.1.
If the room temperature changes when the out-
door temperature changes, you increase/decrease
the curve slope by one step in menu 1.30.1.
Wait 24 hours before making a new setting, so that
the room temperature has time to stabilise.
HOT WATER
"More hot water" When there is a temporary increase in hot
water demand, this menu can be used to select an increase
in the hot water temperature for a selectable time.
You can also select "More hot water" in the main product's
menu 2.1.
VENTILATION
The ventilation in the accommodation can be temporarily
increased or reduced here.
If necessary, the return time for the fan can be changed in
the main product's menu 1.2.5 - "Fan return time". You can
select fan speed (1–4). (To select fan speed 1-4, this setting
must be performed first in menu 4.11.4 - Home screen in the
main product.)
POOL
Here you can change the temperature of the water in the
pool or activate/deactivate heating.
PV SOLAR
You can read off the value of the power that the solar panels
are currently providing.
You can also see how much energy the solar panels have
produced during the current calendar month.
HOME/AWAY
Here you can activate or deactivate the "Away mode" func-
tion.
The function is activated if you select "Away" when you
leave home. To deactivate, select "Home". Settings for "Away
mode" are made in the main product's menu 4.5 - "Away
mode".
28
SMART PRICE ADAPTION™
Information about the current electricity price is displayed
here.
Activation, deactivation and settings are performed in the
main product's menu 4.2.5 - "Smart Price Adaption™".
The function customises some of the installation's consump-
tion during the day to those periods with the cheapest
electricity tariff, which can provide savings if you are on an
hourly-rate electricity contract.
MENU 1 – NIGHT MODE
NIGHT MODE
Alternatives: On/Off
SCHEDULE NIGHT MODE
Setting range: 00.00 – 23.59
You can activate night mode here.
Activate night mode during the time of day you want to
switch off the backlight.
MENU 2 – CONNECTIONS
Select wireless or wired connection.
WIRELESS CONNECTION
Select wireless connection.
Go to the main product and select menu 5.4 – "Connect
wireless units".
WIRED CONNECTION
Select a communication address for RMU S40 by allocating
it a unique number in this menu.
Setting range: 1 – 8
MENU 4 – LICENCES
You can find licences for open source code here.
MENU 5 – SENSOR CALIBRATION
Here, you can calibrate the temperature sensor's value. The
set value is added to, or deducted from, the sensor's current
measured value.
Setting range: -5.0 – 5.0 (Default 0)
MENU 7 – DISPLAY ZONES
Here, you can select the zones that you want to be displayed
in your RMU S40, for heating and cooling.
You can choose to display a maximum of ten zones.
MENU 8 – FACTORY SETTING
Reset to factory setting.
MENU 9 – INFORMATION
Here, information is displayed about the product and the
software version that is installed.