Page 24
LYNX 08 24V
Guide for the installer
Display
Parameter
Value
Behaviour in the event of a power cut: This parameter is used to select the behaviour of the automated system when mains
Without battery kit: If mains power fails, the automated system remains in the position it is in that
0
Without battery kit: If mains power fails, the automated system remains in the position it is in that
1
With battery kit: In the event of a mains power failure, the automated system continues its normal
0
With battery kit: If mains power fails, the control unit automatically commands an opening movement
1
Immediate closure: If this function is activated, when the automated system is open in pause and the photocells detect a
transit, the photocells command an automatic re-closure of the automated system without waiting for the
pause time to elapse
0
Immediate closure disabled
o
1
Immediate closure activated
Immediate closure/Timer: This function is used to select the immediate re-closure of the automated system or stop with the
OPEN/CLOSE input
Immediate closure: When the automated system is open in pause, an impulse of the OPEN/CLOSE
0
P
Timer function: When the automated system is open in pause, an impulse of the OPEN/CLOSE input
1
Fototest: If this function is activated, the control unit performs a check of the correct operation of the connected safety devices
before each closing movement
0
Fototest function disabled
S
1
Fototest function activated
Safety devices: This function is used to select the type of activation of the connected safety devices: active only during the
closing movement of the automated system or active during opening, too.
0
Safety devices active only during the closing movement of the automated system
y
1
Safety devices active during the closing and opening phase of the automated system
power is cut.
moment. When the mains power is present again, the control unit automatically
commands, after two seconds, a beam re-closure and prepares for normal ope-
ration. The first opening movement performed by the automated system occurs
at decelerated speed.
moment. When mains power is present again, send an OPEN or OPEN/CLOSE
pulse to resume normal operation of the automated system. When mains power
is present again, the first two (closing and opening) movements performed by
the automated system occur at decelerated speed. The automated system
resumes normal operation only after having carried out an opening movement
at decelerated speed.
operation. At the end of every opening movement, the flashing lamp (external flashing
lamp or the luminous strip on the upright sides) flashes twice in succession with a 3-
second interval for a max. time of 15 seconds indicating thus that the automated
system is only powered by batteries. The battery charge level is constantly monitored
by the control unit: when the batteries are almost flat, the control unit stops the beam
in open position. It resumes normal operation when mains power is present again.
When the batteries are completely flat, the automated system behaves as if buffer
batteries were not connected.
of the automated system and stops the rod in opening position disabling all commands.
When the mains power is present again, if automatic re-closure was selected, the
control unit automatically commands the beam re-closure and sets for normal
operation. If the automatic re-closure was not selected, when the mains power is
present again, the automated system waits for a CLOSE or OPEN/CLOSE command
to resume normal operation. When batteries are flat, the automated system behaves
as buffer batteries have not been connected.
.
a
input
.
b
command causes the automated system to start the closing phase without waiting
for the pause time to elapse.
causes the control unit to resume the pause time count. If the OPEN/CLOSE command
is held down, the pause time count stops. When the command is released, the control
unit resumes the pause time count and then closes.
.
c
Description