INSTALLATION
Installation
9.
Installation
9.1
Preparing the DHW circulation line connection,
if applicable
You can fit a DHW circulation line to the DHW circulation connec-
tion, or you can use the thermometer connection where appro-
priate (see chapter "Specification / Dimensions and connections").
SB S
Note
Fit the cylinder casing with cover before making the water
connection and, if necessary, the DHW circulation line or
the flanged immersion heater.
The plinth trim should be fitted after the tightness check.
f If you install a DHW circulation line on the DHW circulation
connection, cut an opening in the cylinder casing for the
DHW circulation line near the connection (indentation in the
foam).
f Remove the thermal insulation near the connection.
f Route the DHW circulation line through the opening in the
cylinder casing and fit the DHW circulation line.
f Insulate the "DHW circulation" connection.
f Insert the adaptor supplied with flat gasket and an extension.
f Cover the hole in the cylinder casing with the adhesive rose
supplied.
SB AC
Note
Extend the connection for the DHW circulation line before
fitting the thermal insulation.
f Extend the DHW circulation connection to approx. 150 mm.
f Fit the thermal insulation. For this, observe chapter "Fitting
the thermal insulation".
f Fit the DHW circulation line.
9.2
Fitting the thermal insulation
The thermal insulation is available as accessory.
f Fit the thermal insulation according to the instructions sup-
plied. For this, ensure that there is enough space for the
installation task.
SB 602 AC | SB 1002 AC
f Insert the anode indicator extension through the hole in the
cover plate.
www.stiebel-eltron.com
9.3
Fitting the thermometer
f Insert the thermometer as far as it will go and align it.
9.4
Fitting the signal anode
SB S
Material losses
!
The appliance must not be operated without a consump-
tion indicator or with a damaged one, otherwise water
will leak out once the anode is depleted.
1
1 Transport protection
2 Signal anode with consumption indicator
f Remove the transport protection.
f Check the consumption indicator for transport damage.
2
SB S | SB AC |
19