Cleaning the Carriage and Food Grip
Disconnect the appliance from the power supply.
1.
Lift the food grip from the cradle.
2.
Tilt the cradle away from the appliance [Fig. 1].
3.
Wash with warm soapy water.
4.
Dry thoroughly.
5.
Cleaning / Changing the Blade
Disconnect the appliance from the power supply.
1.
Push the carriage away from the blade.
2.
Unscrew and remove the centre plastic cap securing the blade.
3.
Carefully lift the blade from the appliance.
4.
Wash the blade by wiping from the centre towards the edge.
5.
Dry thoroughly.
6.
Replace the blade, ensuring the centre plastic cap is securely tightened.
7.
Note: Caterlite recommend the use of cut-resistant or wire mesh gloves when cleaning the
blade.
Cleaning Behind the Blade
With the blade removed use a slightly damp cloth to clean the area behind the blade.
Dry thoroughly before replacing the blade.
Troubleshooting
Fault
The unit is not working
The unit is not working
The cradle does not move
smoothly along the carriage
3
Probable Cause
The unit is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Food trapped beneath cradle
Action
Check the unit is plugged in correctly
and switched on
Call Caterlite agent or qualified
technician
Replace the plug fuse
Check power supply
Call Caterlite agent or qualified
technician
Tilt cradle and clean carriage