Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The arm of the shower head is intended only to hold
the shower head. Do not load it down with other
objects!
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
Do not allow the streams of the shower touch sen-
sitive body parts (such as your eyes). An adequate
distance must be kept between the shower and you.
The product may not be used as a holding handle. A
separate handle must be installed.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal pressu-
res.
Installation Instructions
Important! The fitting must be installed, flushed and
tested after the valid norms.
Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels are
only suitable for concrete. For another wall construc-
tions the manufacturer's indications of the dowel
manufacturer have to be taken into account.
The filter insert (A) must be used to ensure the
standard flow rate and to protect the hand shower
against incoming dirt by pipework. Do you want a
larger water flow rate, then you must use the filter
packing (B) instead of the filter insert (A). Incoming
dirt leads to defects or/and can damage parts of the
hand shower; such caused faults voids all liability and
guarantee claims.

English
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G 1/2:
anti-pollution function
Symbol description
Assembly see page 35-39
Do not use silicone containing acetic acid!
To adjust the hot water limiter on single lever
mixers, please see page 40. No adjustment is
necessary when using a continuous flow water
heater.
Maintenance (see page 41)
The non return valves must be checked regu-
larly according to DIN EN 1717 in accor-
dance with national or regional regulations (at
least once a year).
Dimensions (see page 31-34)
Flow diagram (see page 31-34)
Spare parts (see page 47)
Cleaning (see page 44-46) enclosed
brochure
Operation (see page 42-43)
max.1 MPa
0,15 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
150±12 mm
cold right - hot left