Download Inhoudsopgave Inhoud Print deze pagina

Qlima PGWH1010 Gebruiksaanwijzing pagina 43

Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 54
6.
The appliance maintenance operations necessary to enable it to be put back into
service after these devices have operated.
7.
If this device or one of their parts are dismantled previously existing seals shall be
remade.
8.
Only manufacturer's original parts should be used for replacements.
9.
WARNING: The safety device shall not be put out of operation. Inappropriate
interference with the safety device can cause serious injuries and/or damage.
If you fail to consult and/or follow up the rules, instructions and explanation, the
warranty will no longer be valid, and the manufacturer will no longer deal with any
damage to the appliance and/or your environment under the warranty.
The use of this product and the elements required for that purpose is entirely at the
end user's own risk.
TROUBLESHOOTING
PROBLEM
No flame/no ignition in winter
(temp. <7 °C)
No flame
Yellow flame instead of blue flame
SOLUTION
Check whether butane or propane is being used: buta-
ne will burn ever more poorly as the temperature drops
below 7 °C because it then turns into liquid. With LPG
(=propane/butane mixture), it will often help to give
the gas cylinder a shake.
- Too low water flow. Solution: Increase water flow.
- Too low water pressure. Solution: Increase water pres-
sure to a pressure > 0.03 MPa.
- The pressure relief valve is open. Solution: Tighten the
pressure relief valve by turning the valve clockwise.
- Not enough gas: Exchange gas bottle.
Contact service center immediately for help.