Download Print deze pagina

EIBENSTOCK EBS 1802 Oorspronkelijke Gebruiksaanwijzing pagina 20

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 47
Dust Extraction
Dust which occurs during your work is hazardous to health. That is why the
concrete grinder must be used with a vacuum cleaner, and a dust mask
has to be worn. The suitable Wet/Dry Vacuum Cleaner (dust category M) is
available as accessory. It can directly be attached to the connection on the
dust hood.
Changing the brush rim
If the length of the brushes is – due to wear - smaller than 5 mm (extreme
formation of dust during grinding), the brush rim has to be replaced
completely.
Therefore, remove the three fixing screws of the firm part of the dust guard
and the two fixing screws of the detachable part. Pull out the worn brush
rim and replace it by a new one. Pay attention that the fastening holes in
the brush rim and the holes of the dust hood have the same same position.
Screw both parts together.
Instruction for Use
Only use combinations of diamond cutting discs, concrete grinders with
mounted guard and extraction hood as well as dust category M vacuum
cleaners that are recommended by EIBENSTOCK. Other combinations can
lead to insufficient dust collection and separation.
Switch the machine on and put it carefully on the surface you want to work
on. Hold the tool with both hands and work with circular or linear
movements.
For best working results: Don't put too much pressure on the surface you
want to work on.
For grinding works right into edges of the wall one
segment of the dust guard can be opened. This allows
grinding on surfaces which are usually hard to reach.
Attention!
All other grinding works have to be done with the complete dust
guard.