Download Inhoudsopgave Inhoud Print deze pagina

Safety Notes; Installation Instructions; Technical Data - Hansgrohe PuraVida 15066000 Gebruiksaanwijzing

Verberg thumbnails Zie ook voor PuraVida 15066000:
Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 7

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
• If the water is flowing along the fixture in the direction
of the shaft, the spray former must be replaced with a
standard air bubbler 95928000.
• The drain valve must only be used as intended. It is not
allowed to attach other objects to the drain valve, for
example a semi-pedestal.
• The drain valve may only be installed in basins with
an overflow opening.
• If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart
(flow limiter) located behind the aerator can be
removed.
Special information for UK
If installing this product with a pump, please be aware
that it has to have negative head switching. This product
will not function with a positive head pump..
4
English

Technical Data

This mixer series-produced with EcoSmart
(flow limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Symbol description
®
Assembly see page 31
Do not use silicone containing acetic acid!
Dimensions (see page 32)
Flow diagram
(see page 33)
with EcoSmart
®
without EcoSmart
®
Spare parts (see page 35)
Operation (see page 34)
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn
in the morning or after a prolonged period
of non-use.
Cleaning (see page 36) and en-
closed brochure
Test certificate (see page 40)
®
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
max. 70°C / 4 min

Advertenties

Inhoudsopgave
loading

Inhoudsopgave