Troubleshooting guide
DANGER
Danger of electric shock
Injuries due to touching live parts
Switch off the device.
Remove the mains plug.
Note
The device must be switched off immediately if a
malfunction occurs (e.g. filter breakage). The mal-
function must be eliminated before switching the
device on again.
Suction turbine does not start up
1. Check the socket and the power supply fuse.
2. Check the mains cable, mains plug, electrodes
and power socket on the device.
3. Switch on the device.
Suction turbine switches off
1. Empty the container.
2. Fit the new flat fold filter.
Suction turbine does not switch on again after
emptying the container
1. Switch off the device, wait for 5 seconds and
then switch on again after waiting for 5 sec-
onds.
2. Clean the electrodes with a brush.
Suction power decreases
1. Remove any blockages from the suction nozzle,
suction pipe, suction hose or flat fold filter.
2. Change the filled fleece filter bag.
3. Dispose of the filled dust bag.
4. Correctly engage the filter cover.
5. Replace the flat fold filter.
Escaping dust when vacuuming
1. Check that the flat fold filter is correctly fitted
and correct if necessary.
Figure M
2. Replace the flat fold filter.
The automatic switch-off mechanism (wet vacuum
cleaning) does not trigger
1. Clean the electrodes with a brush.
2. Continuously monitor the filling level when vac-
uuming non-conductive liquids.
Horn sounds - intermittent tone
1. Set the turn switch to the correct hose cross-sec-
tion.
24
2. The fleece filter bag must be replaced when it
is full and the air flow drops below the specified
minimum flow rate.
3. The dust bag must be replaced when it is full
and the air flow drops below the specified min-
imum flow rate.
4. Replace the flat fold filter.
Horn sounds - continuous tone
1. Allow the device to cool down. Clean/replace
the cooling air filter.
Automatic filter dedusting not working
1. Suction hose not connected.
The automatic filter dedusting function cannot be
switched off
1. Contact Customer Service.
The automatic filter dedusting function cannot be
switched on
1. Contact Customer Service.
Customer Service department
If the malfunction cannot be corrected, the device
must be checked by the Customer Service depart-
ment.
At the end of its service life, the device is to be dis-
posed of in accordance with statutory regulations.
 For this Würth vacuum cleaner, we offer a guar-
antee in accordance with the statutory/coun-
try-specific provisions from date of purchase (in-
voice or delivery note is required as proof). Any
damage that has occurred will be resolved by
replacement delivery or repair.
 The guarantee excludes damage resulting from
normal wear, overloading or improper han-
dling.
 Complaints can only be accepted if the vacuum
cleaner is returned fully assembled to a Würth
branch, your Würth Sales Representative or
Würth Master Service.