Download Print deze pagina

Würth ISS 40-M AUTOMATIC Vertaling Van De Originele Gebruiksaanwijzing pagina 20

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 68
Installing the fleece filter bag
1. Unlock and remove the suction head.
2. Fit the fleece filter bag.
Figure A
3. Fit and lock the suction head.
Installing the dust bag
Note
The dust bag opening must be pulled fully over the
suction hose port.
1. Unlock and remove the suction head.
2. Fit the dust bag.
Figure B
3. Pull the dust bag over the container.
4. Fit and lock the suction head.
Wet vacuum cleaning
DANGER
Danger from dust that is harmful to your
health
Respiratory sicknesses through inhala-
tion of dust.
No dusts harmful to health may be vacu-
umed when performing wet vacuum
cleaning.
Closing the suction connection
1. Fit a plug exactly into the suction connection.
Figure C
2. Push the plugs in until they engage.
Removing the fleece filter bag
 The fleece filter bag must always be removed
when vacuuming wet substances.
1. Unlock and remove the suction head.
2. Pull the fleece filter bag out to the rear.
Figure D
3. Fold in the lock latch and seal the fleece filter
bag tight.
4. Dispose of the used fleece filter bag in accord-
ance with statutory regulations.
5. Fit and lock the suction head.
Removing the dust bag
 The dust bag must always be removed when
vacuuming wet substances.
1. Unlock and remove the suction head.
2. Fold up the dust bag.
Figure E
20
3. Pull the dust bag opening towards the rear over
the suction hose port.
4. Seal the dust bag tightly underneath the open-
ing using cable ties.
5. Remove the dust bag.
6. Dispose of the dust bag in accordance with
statutory regulations.
7. Fit and lock the suction head.
 We recommend switching off the "Automatic fil-
ter dedusting" function when vacuuming wet
dirt with the crevice nozzle or when sucking
mainly water out of a container.
 The device switches off automatically when the
maximum fluid level is reached.
 When vacuuming non-conductive liquids (e.g.
drill emulsion, oils and grease) the device does
not automatically switch off when the container
is full. The filling level must be continuously mon-
itored and the container emptied on a timely
basis.
 On completion of wet vacuum cleaning: Clean
the electrodes with a brush. Clean the contain-
er with a moist cloth and dry it off.
Clip connection
The suction hose is equipped with a clip system. All
accessory parts with a nominal width of 35 mm
can be connected.
Figure F
Device OFF
Device ON
Automatic filter dedusting: OFF
Device ON
Automatic filter dedusting: maximum
interval
English
General
Operation
Turn switch

Advertenties

loading

Deze handleiding is ook geschikt voor:

Iss 40-m automatic ch0701 143 series