Servicing/maintenance
Danger!
Danger due to inadvertent triggering.
Disconnect the compressed air supply before all maintenance and service work.
Danger!
Voltage hazard.
All operations which necessitate opening the device may be performed only by qualified
electricians.
Burn hazard!
Nozzle (1) and molten adhesive can be over 200 °C hot. Wear heat-resistant gloves
when performing servicing and maintenance operations.
6.1
Service intervals
Observe the stated service intervals to ensure always correct and reliable operation:
Weekly:
Inspect and if necessary drain the service-unit water separator (see Fig. 6.1/1)
Check that all parts are present, leak-free and undamaged and all screws and lines securely
seated
Remove adhesive residues and other contaminants, especially on the inside of the cover
Fig. 6.1/1:
6.2
Cleaning
• Do not use aggressive cleaning agents for cleaning the device. These may damage
device components.
We recommend cleaning with paraffin oil.
• Replace completely parts which are no longer cleanable (e.g. because of burnt-on or
reacted hot-melt adhesive). We recommend having this work done by the manufacturer
or distributor.
• Remove residues of hot-melt adhesive and other contaminants by mechanical means
only, e.g. with a cloth, soft brush, wooden spatula or similar.