INSTALLATION AND MAINTENANCE GUIDE
Technical data
Working pressure
Flow-rate at 300 kPa
Pressure loss with flow (0.2 l/s)
Noise class
Electrical connection
Protection class
Hot water supply
Recognition range (touchless function)
Afterflow period (touchless function)
Max. flow period (touchless function)
Dishwasher valve open period
Models
Oras Ventura kitchen faucet models:
– 8020: kitchen faucet with touchless faucet and dishwasher connection (see figure 1).
– 8025: kitchen faucet with touchless faucet and electronic dishwasher valve (see figure 2).
Installation of the faucet (see figure 3)
– Thread the socket (1) with the operating switch of the electronic dishwasher valve over the
installation aperture so that the switch points either to the right or to the left.
– Push the faucet in place into the installation aperture (ø 34 – 37 mm), then ensure that the sealing at
the base of the faucet or the socket is in place and that the wires from the faucet and the operating
switch do not get squeezed.
– Position the support plate (2) and tightening plate (3), and screw on the nuts (4) by hand. Turn the
touchless faucet to desired position and then tighten the nuts with a 9 mm wrench.
– Attach the inlet pipe of the touchless faucet's spout. Note! Left-hand thread in the inlet pipe.
Installation of the mixer unit
Figure 4
– Screw on the mounting plate (5) of the mixer unit at a suitable height.
– Hang the mixer unit to the holes of the mounting plate.
– Attach the faucet inlet pipes with their sealings to the mixer unit couplings according to the colour
codes.
– Attach the PEX pipes to the mixer unit couplings.
– Cut the pipes to a suitable length, insert the support sleeves (7) to the pipes and attach them to the
inlet pipes.
Figure 5
– Attach the sensor connector (8) to the right-hand side connector of the mixer unit.
Model 8020:
– If the connector (10) is used, remove the plug (11).
– If the connector (10) is used without a dishwasher valve, it does not meet the
requirements set for it in the Nordic countries.
Model 8025:
– If the connector (10) is used, remove the plug (11).
– Attach the dishwasher connector (9) to the left-hand side connector of the mixer unit.
– Connect the plug transformer to a wall socket.
– Open the water inlet to the faucet and check that the joints are tight.
100 – 1000 kPa
0.21 l/s
272 kPa
I (ISO 3822)
230/12 VAC
IP 30
max. 80°C
2 cm, (0 - 6 cm)
3 s, (1 - 10 s)
40 s
150 min, (60 - 210 min/12h) (in model 8025)
13
GB