Oil burner
TECHNICAL FEATURES
Thermal power – output
Fuel
Electrical supply
Motor
Capacitor
Ignition transformer
Pump
Absorbed electrical power
n
For use on hot air generator the burner must be fitted with control box type 479SE or 539SE.
n
Burner with CE marking in conformity with EEC directives: EMC89/336/EEC, Low Voltage 73/23/EEC,
Machines 89/392/EEC and Efficiency 92/42/EEC.
n
The burner meets protection level of IP 40, EN 60529.
n
DIN Certification No. : 5G348 / 94 as EN 267.
8
4
3
1 – Return line
2 – Suction line
3 – Gauge connection
4 – Pump pressure regulator
5 – Vacuum gauge connection
6 – Screws fixing air-damper
7 – Hydraulic jack with air-damper
8 – Lock-out lamp and reset button
9 – Flange with insulating gasket
10 – Combustion head adjustment screw
2351
All manuals and user guides at all-guides.com
G10
CODE
54 – 120 kW
Gas oil, max. viscosity at 20 ° C: 6 mm
Single phase, 230 V ± 10%
Run current 0.80 A – 2850 rpm – 298 rad/s
4 m F
Secondary 8 kV – 16 mA
Pressure 7 – 15 bar
0.170 kW
D5668
3746412
–
4.5 – 10 kg/h
~
Fig. 1
7
6
6
9
EQUIPMENT
Quantity
2
Flexible pipes with nipples
1
Flange with insulating gasket
2
Screws and nuts for flange
1
Hinge
1
Screw with two nuts for flange
1
GB
464T1
TYPE
/s (1.5 ° E)
2
50Hz
10
2
1
Description