Attention: if the GSM LED continues to flash every second, the modem is not working (cor-
rectly). Turn off the Mobile SMS Guard 300, wait ten seconds and then turn it on again. If
after a minute the GSM LED still flashes every second, you can try it again with a SIM card
from a different provider. If the GSM LED does not light up, the SIM card has not been placed
correctly.
Step 5 Placing the door/window sensors
Figure 5
•
Standard, two door/window sensors are included. Take the top and bottom parts apart.
You will now see the space to insert a 9V battery. Open the top part even further. You
will now see a black square with 8 jump switches. See figure 5. Use the same security
code as you used for the Mobile SMS Guard 300 (step 3). Insert a 9V battery (not
included) in the battery compartment of the sensors: Make sure the polarity is correct
when inserting the battery and close the top part of the sensor.
•
Place the sensor as high up as possible: this guarantees the best possible range. Mark the
place for the transmitter and the magnetic contact. Do not place the magnetic contact
directly onto a metal surface. In the case of metal frames, or metal-fortified PVC frames,
it is best to place a piece of wood or plastic of min. 5 mm in between the magnetic
contact and the frame. On metal frames, the space between the sensor and the magnet
should not be more than 3 mm when the door or window is closed.
•
Switch on the door/window sensor by flicking the switch on the left-hand side, 0 = OFF,
I = ON. The red LED (sun icon) will light up. Hold the magnetic sensor to the right-hand
side of the sensor. As soon as the red LED is extinguished, the two parts of the sensor
make contact properly. Position the magnetic sensor in such a way that the red LED
remains off when the door or window is closed. Make sure that the distance between
the transmitter and magnetic sensor parts are as small as possible. (max. 4 mm)
•
If you have countersunk frames, you can also place the transmitter and magnetic sensors
parts at a 90 degree angle.
•
If you have determined the definitive place for the sensor, we advise you to mount the
magnetic contact using screws (not included).
•
Sliding/sash windows
In the case of sliding/sash windows, the sensor and the magnet should NOT rub over
each other. Place them in such a way that, if you close the window, the magnet and
sensor approach each other vertically.
•
If the door/window sensors and magnetic sensors are correctly mounted and are
activated, continue with step 6.