Error
The multimeter
does not work.
No measuring
change.
Repairs other than those described should only be carried out by an authorised specialist.
If you have queries about handling the measuring device, our technical support is available
under the following telephone number:
Voltcraft®, 92242 Hirschau, Lindenweg 15, phone 0180 / 586 582 7
Technical data
Display ........................................................2000 counts (4000 counts with the VC170)
Measuring frequency ..................................approx. 2-3 measuring operations/second
Measuring lead length ................................about 75 cm each
Measuring impedance ................................>10MΩ (V range)
Operating voltage ........................................9V block battery
Working temperature ..................................0°C to 40°C
Operating altitude ........................................max. 2,000 m
Storage temperature....................................-10°C to +50°C
Weight ........................................................ca. 200 g
Dimensions (LxWxH) ..................................137 x 72 x 35 (mm)
Over-voltage category ................................CAT III 250 V
Measurement tolerances
Statement of accuracy in ± (% of reading + display error in counts (= number of smallest points)). The
accuracy is valid for one year at a temperature of +23°C ± 5°C, and at a relative humidity of less than
75%, non-condensing.
All manuals and user guides at all-guides.com
Possible cause
Is the battery dead?
The HOLD function is activated
(display shows "H")
Is the wrong measuring function
active (AC/DC)?
Did you use the wrong measuring
sockets?
Is the fuse defect?
Remedy
Check the status.
Press the button "HOLD" again.
The symbol "H" disappears.
Check the display (AC/DC) and
switch the function if applicable.
Check the measuring sockets.
In A/mA/µA range: Change the
fuse as described in the chapter
"Changing the fuse".
43