All manuals and user guides at all-guides.com
8. DMX connection
You can operate a maximum of 30 DL-PAR103 in a DMX chain without overloading the control-
ler.
The maximum total length of the DMX chain should not exceed 100 m.
Use of XLR microphone cables may cause interferences in the DMX signal transmission. In this
case, please use special DMX high-frequency cables.
Connection of a DMX controller
Only connect the device to a DMX controller with a DMX-512 protocol.
• Connect the DMX IN DMX input to the DMX controller output.
• Use a screened XLR cable for this. The controller must have 8 free control channels.
• Connect the DMX OUT DMX output with the DMX input of the next device in sequence. If the effect light
is the last or only device in the DMX chain, insert a plug with a 120 Ohm/0.25 W terminator here (between
Pin2 and Pin3).
Pin assignment of the DMX connection: Pin1 = earth / Pin2 = (-) / Pin3 = (+).
Never connect the earth pin GND to the casing earth of the effect light; this may result in inter-
ference in signal transmission caused by ground loops.
28