BMS and three battery modules
BMS to Battery1:
• B+ to B+: Power cable (120 mm) (MC0600: part B)
• COMM to COM1: COMM communication cable (200 mm) (MC0600: part A)
• Grounding cable: 150 mm (MC0600: part F)
Battery1 to Battery2:
• B- to B+: Power cable (690 mm) (HV10230: part B)
• COM2 to COM1: COMM communication cable (600 mm) (HV10230: part A)
• Grounding cable: 450 mm (HV10230: part E)
Battery2 to Battery3:
• B- to B+: Power cable (1200 mm) (T30 Base: part I)
• COM2 to COM1: COMM communication cable (1200 mm) (T30 Base: part J)
• Grounding cable: 1200 mm (T30 Base: part K)
Battery3 to BMS:
• B- to B-: Power cable (1800 mm) (Accessory kit (2): part B)
Waterproof cap
Buckle it
Battery3
The guard ring (T30 Base: part E) should
be used to protect the corrugated pipe.
Two guard rings are required to be used.
Rotation wrench
BMS
(MC0600: Part J)
Battery1
Battery2
95