*Note:
1. To prevent short circuits, the power cables between the BMS and the battery module
must be connected first when conducting the wiring of the whole system.
2. A rotation wrench is used to tighten both ends of the communication cable, and it may
be removed after tightening.
3. A waterproof cap shall be put on the unconnected COM port.
BMS and four battery modules
BMS to Battery1:
• B+ to B+: Power cable (120 mm) (MC0600: part B)
• COMM to COM1: COMM communication cable (200 mm) (MC0600: part A)
• Grounding cable: 150 mm (MC0600: part F)
Battery1 to Battery2:
• B- to B+: Power cable (690 mm) (HV10230: part B)
• COM2 to COM1: COMM communication cable (600 mm) (HV10230: part A)
• Grounding cable: 450 mm (HV10230: part E)
Battery2 to Battery3:
• B- to B+: Power cable (1200 mm) (T30 Base: part I)
• COM2 to COM1: COMM communication cable (1200 mm) (HV10230: part A)
• Grounding cable: 1200 mm (T30 Base: part K)
Battey3 to Battery4
• B- to B+: Power cable (690 mm) (HV10230: part B)
• COM2 to COM1: COMM communication cable (1200 mm) (T30 Base: part J)
• Grounding cable: 450 mm (HV10230: part E)
Battery4 to BMS:
• B- to B-: Power cable (1200 mm) (Accessory kit (2): part A)