INSTALLATION
Safety
INSTALLATION
7.
Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
7.1
General safety instructions
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
7.2
Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
8.
Appliance description
The appliance heats DHW electrically. Once the selected temper-
ature has been reached, the temperature limiter switches the
appliance off.
8.1
Standard delivery
The following are delivered with the appliance:
- Fill/drain tap
- Wall mounting bracket
- Two screws, two rawl plugs, two washers
- Installation template
8.2
Accessories
Replacement drain taps, replacement pivoting spouts and drain
outlets with stench traps are available as accessories.
9.
Preparations
9.1
Installation site
Always install the appliance vertically (oversink) in a frost-proof
room.
10. Installation
10.1 Appliance installation
See also chapter "Alternative installation methods".
20
| EBK | KBA
45
f Using the installation template, transfer the dimensions of
f
the wall mounting to the wall. To do so, loosely screw the in-
stallation template with tap connection to the wall.
f Drill the holes.
f
EBK 5 K
1
2
1 Twin connector with throttle screw
2 Plastic sleeve
3 White-coated two-handled lever tap
f Screw in the twin connector.
f
f Slide the plastic sleeve onto the twin connector.
f
105
+15
3
1 Screw depth specification
2 White-coated two-handled lever tap with throttle screw
f Screw in the tap, taking care to observe the screw depth
f
specification.
f Attach the tap outlet.
f
KBA 5 KA
105
+15
3
1 Screw depth specification
2 Chrome-coated three-handled tap with throttle screw
3 Extensions
f Screw in the tap with the extensions, taking care to observe
f
the screw depth specification.
f Attach the tap outlet.
f
3
1
2
1
2
www.stiebel-eltron.com