Use suitable detectors to determine if utility lines are hidden in the
work area or call the local utility company for assistance. Contact with
electric lines can lead to fire and electric shock. Damaging a gas line can
lead to explosion. Penetrating a water line causes property damage or may
cause an electric shock.
When working stone with dry cutting, use dust extraction. The vacuum
cleaner must be approved for the extraction of stone dust. Using this
equipment reduces dust-related hazards.
When working with the machine, always hold it firmly with both hands
and provide for a secure stance. The power tool is guided more secure
with both hands.
Never use the machine with a damaged cable. Do not touch the
damaged cable and pull the mains plug when the cable is damaged
while working. Damaged cables increase the risk of an electric shock.
For further safety instructions, please refer to the enclosure!
Before starting the machine check the correspondence between voltage and
frequency according to the data mentioned on the identification plate. Voltage
differences from + 6 % and – 10 % are allowed.
The angle grinder is made in protection class II.
Only use extension cables with a sufficient cross-section. A cross-section which
is too small could cause a considerable drop in performance and an
overheating of machine and cable.
Recommended minimum cross sections and maximum cable lengths
Mains voltage
110V
230V
The tool is equipped with a start-up speed limiter to prevent that swift automatic
circuit breakers are unintentionally triggered.
For protection purposes the ETR 350 P can only be run with a GFCI. The
machine is standard equipped with a PRCD protective switch integrated in the
cord.
Attention!
The PRCD protective switch must not lay in water.
!
PRCD protective switches must not be used to switch
Before starting your work, check the proper function
Electrical Connection
Cross section in sq. mm
1.5
-
50 m
the tool on and off.
by pressing the TEST button.
2.5
40 m
80 m
22